Enter your keyword

Low NOx Emissions with Fuel Conversion and Co-Firing

CASE STUDY

Low NOx Emissions with Fuel Conversion and Co-Firing

Low NOx Burner

A North American utility company needed to convert a tilting tangential oil‐fired boiler to a dual fuel (natural gas and oil) unit. Additionally, heavy oil NOx emissions were to be reduced from the current low NOx burner levels. Unit Description: CE tangential #6 oil fired VE superheat unit. Eight (8) tilting tangential burners with two (2) burners per corner and eight (8) class 1 light oil igniters. The unit was designed to supply 450 kpph of steam at 1475 psig and 955°F.

STEP provided 8 dual fuel 90MMBtu/hr Low NOx natural gas and heavy oil burners for each boiler. The burners were equipped with automatic retracts and gun coupled limit switches. STEP also provided Class 1 natural gas igniters with flame detection rods, and UV+IR+V fiber optic main flame scanners, tuned for individual burner discrimination.

Both gas and oil performance surpassed the guarantees. The new burner reduced heavy oil NOx emissions by 25%, while natural gas NOx emissions of less than 0.1 lbm/MMBtu were achieved. The low NOx performance was achieved without the use of flue gas recirculation or over‐fire‐air, while maintaining low CO and opacity.